Sun Photometer Data (RAW) 2014 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2013 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2012 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2011 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (AOD) 2014 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2013 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2012 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2011 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (RAW) 2020 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2019 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2017 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2016 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (RAW) 2015 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time... -
Sun Photometer Data (AOD) 2020 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2019 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2017 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2016 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (AOD) 2015 from Zeppelin Station, Ny-Ålesund, Svalbard (A...
Aerosol optical depth (AOD) is measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1°... -
Sun Photometer Data (RAW) from Zeppelin Station, Ny-Ålesund, Svalbard (AWIPEV)
Voltages are measured by a sun photometer, type SP1a by Dr. Schulz & Partner GmbH in 17 wavelengths between λ = 369nm to 1023nm with a field of view of 1° × 1° and a time...