4DCT XCAT phantom dataset for "Resolving Variable Respiratory Motion From Unsorted 4D Computed Tomography", MICCAI2024

DOI

The XCAT phantom dataset used in our paper "Resolving Variable Respiratory Motion From Unsorted 4D Computed Tomography", MICCAI 2024. For details on how to use the dataset, please visit https://github.com/Yuliang-Huang/4DCT-irregular-motion. If you find this dataset useful for your research, please cite our MICCAI paper.Note: We thank Prof Paul Segars from Duke University for the permission of releasing this single simulation example. If you want to use the XCAT software, please contact him.Introduction to the dataset:A digital phantom of thoracic region with motion was generated by the 4DXCAT software [1] and post-processed by the cid-X software [2]. The simulation was controlled by two respiration traces, i.e. the motion of the chest and the diaphragm, which were measured from 2D Cine MRI from a real patient. The diaphragm trace was deliberately delayed by 1 second to add hysteresis, i.e. the breathing would follow different paths during inhalation and exhalation. The chest trace could simulate the skin marker or belt signals normally used to sort 4DCT data in clinical practice and was stored in the rpm_signal.txt file.The phantom dataset consisted of images of thoracic regions at 182 timepoints in NIFTI format, each with size 355x280x115 voxels and resolution of 1x1x3 mm. Binary masks of the tumour were also provided for each timepoint. The dynamic volumes and tumor masks can be found in the compressed ground_truth.zip folder.The ref_empty_image.nii.gz file is an image with zero voxel values that define the reference image space. The ref_tumor_mask.nii.gz is the ground-truth tumor mask at the time average position.References:[1]Segars, W.P., Sturgeon, G., Mendonca, S., Grimes, J., Tsui, B.M.: 4d xcat phantomfor multimodality imaging research. Medical physics 37(9), 4902–4915 (2010)[2]Eiben, B., Bertholet, J., Menten, M.J., Nill, S., Oelfke, U., McClelland, J.R.: Con-sistent and invertible deformation vector fields for a breathing anthropomorphicphantom: a post-processing framework for the xcat phantom. Physics in Medicine& Biology 65(16), 165005 (2020)

Identifier
DOI https://doi.org/10.5522/04/26132077.v1
Related Identifier HasPart https://ndownloader.figshare.com/files/47332975
Related Identifier HasPart https://ndownloader.figshare.com/files/47332978
Related Identifier HasPart https://ndownloader.figshare.com/files/47332981
Related Identifier HasPart https://ndownloader.figshare.com/files/47332984
Related Identifier HasPart https://ndownloader.figshare.com/files/47332987
Metadata Access https://api.figshare.com/v2/oai?verb=GetRecord&metadataPrefix=oai_datacite&identifier=oai:figshare.com:article/26132077
Provenance
Creator Huang, Yuliang
Publisher University College London UCL
Contributor Figshare
Publication Year 2024
Rights https://creativecommons.org/licenses/by-nc-nd/4.0/
OpenAccess true
Contact researchdatarepository(at)ucl.ac.uk
Representation
Language English
Resource Type Dataset
Discipline Other