Addendum to the corresponding paper. The paper describes numerical and experimental investigations of cut-outs of functionally graded concrete slabs subjected to fire exposure in a small scale test furnace.
The data set includes:
experimental_results/
Temperature measurements after 0, 30, 60 and 90 minutes of fire exposure from the specimens subjected to fire in the test furnace.
abaqus_input/
Abaqus .inp files that allow the reproduction of the described numerical simulation for different mesh refinements.
numerical_results/
Simulated temperature after 0, 30, 60 and 90 minutes of fire exposure from the numerical simulations used for a convergence study, to judge the influence of varying boundary conditions and for comparison with the experimental results.
The Abaqus .inp files as well as the files containing the numerical results are designated with the following key composition:
Investigated component:
HB: Hollow Body Slab
FS: Massive Slab
Mesh-Size:
uf: ultra-fine
f: fine
m: medium
c: coarse
Boundary Conditions:
infi: Cutout of a slab with
rest: Specimens as placed in furnace
Thermal material properties:
lc-1_cp-00: High thermal conductivity, low specific heat capacity (humidity 0 %)
lc-2_cp-30: Low thermal conductivity, high specific heat capacity (humidity 3 %)