Masses of individual polychlorinated biphenyl congeners in particle phases in air in Chicago, Il, USA in 2009

DOI

We report the levels of airborne individual PCB concentrations of particle phases from the City of Chicago in 2009. Seventeen locations were sampled for particle phases, where 46 particle phases were collected. One hundred and seventy-one individual or coeluting congener PCBs are reported. This dataset includes the sample mass for all 171 individual congeners for particle (QFF) phases, the deployment time and sampling flow.

  • Individual PCB congener mass in particle phase using high-volume air sampler (i.e., HiVol QFF) Quantification and determination of individual PCB congeners using GC-MS/MS Values = 0 indicates non-detected
Identifier
DOI https://doi.org/10.1594/PANGAEA.935235
Related Identifier IsPartOf https://doi.org/10.1594/PANGAEA.935238
Related Identifier IsSupplementTo https://doi.org/10.1016/j.scitotenv.2021.151505
Related Identifier References https://doi.org/10.1016/j.scitotenv.2022.153263
Metadata Access https://ws.pangaea.de/oai/provider?verb=GetRecord&metadataPrefix=datacite4&identifier=oai:pangaea.de:doi:10.1594/PANGAEA.935235
Provenance
Creator Martinez, Andres ORCID logo; Awad, Andrew M ORCID logo; Hornbuckle, Keri C ORCID logo
Publisher PANGAEA
Publication Year 2021
Funding Reference National Institute of Environmental Health Sciences https://doi.org/10.13039/100000066 Crossref Funder ID P42ES013661 https://iowasuperfund.uiowa.edu/ Iowa Superfund Research Program
Rights Creative Commons Attribution 4.0 International; https://creativecommons.org/licenses/by/4.0/
OpenAccess true
Representation
Resource Type Dataset
Format text/tab-separated-values
Size 8142 data points
Discipline Earth System Research
Spatial Coverage (-87.735W, 41.653S, -87.534E, 41.995N); Chicago, USA
Temporal Coverage Begin 2009-01-06T08:00:00Z
Temporal Coverage End 2009-12-04T15:00:00Z